I have a SPA-3102, how do I setup a static IP and configure port forwarding via the I-connect 62x series (621-625)

Views: 483
Votes: 0
Posted: 12 Jun, 2007
by: Engin *.
Updated: 29 Oct, 2007
by: Engin *.
Overview

Step 1: Find your IP
  1. Disconnect your PSTN line from the LINE socket. By the term "PSTN ", we are referring to your regular landline provider
  2. Dial **** 110 # to listen to your IP address of your SPA-3102
Step 2: Enter your IP address via the web interface
  1. Enter the IP address into your web browser
  2. Go to the WAN Setup menu
  3. Select Static IP
  4. Enter IP address : 192.168.1.10
  5. Enter Gateway Address: 192.168.1.254
  6. Enter Subnet mask: 255.255.255.0
  7. Submit all changes

Step 3: Login to your Open hardware
  1. First login by going to your web browser and typing http://192.168.1.254
  2. enter the username: root, password 0P3N
Step 4: Setup Port Forwarding
  1. Go to the Advanced
  2. Go to Port Forwarding
Step 5: Setup a custom rule for engin
  1. Go to the User Tab
  2. Click the New Tab

Step 6: Add engin as a rule
  1. The Rule Management interface will appear
  2. Enter the Rule name as " engin"
  3. Enter Protocol "UDP"
  4. Enter Port Start  "5060"
  5. Enter Port End" "5060"
  6. Enter Port Map "5060"

Step 7: Setup RTP ports under the same rule
  1. You can enter enter ports 16384-20384 under the same name as " engin"  Repeat the same process of RTP ports.
  2. Enter Protocol "UDP"
  3. Enter Port Start  "16384"
  4. Enter Port End" "20384"
  5. Enter Port Map "16384"

Step 8: Setup Your LAN client (the engin voicebox IP)
  1. Select the LAN connection. In almost all cases this will be the default LAN group 1
  2. Enter the engin voicebox IP as 192.168.1.10
  3. Click Apply
Step 9: Configure LAN client for the engin port forwarding rule
  1. Go back to the "User" PF menu option
  2. Select the rule name "engin"
  3. Ensure the rule is configured to the IP address of 192.168.1.10
  4. Click Apply
  5. Save all changes