How do I setup a different ring for certain inbound calls via my Linksys SPA-3102?

Views: 260
Votes: 3
Posted: 30 Aug, 2007
by: Engin *.
Updated: 08 Aug, 2008
by: Engin *.
Overview

You can define 8 ring patterns (cadences) for SPA-3102. You can select a default ring for any inbound call using 8 different ring patterns. The user can also define a list of caller patterns with each ring pattern so that the ring is played when the caller-id matches the pattern. For example, one can associate Ring 2 with "039012*,039013*", so that whenever caller with 039012 and 039013 area code will use Ring 2 to ring.

Step 1: Accessing your unit
  1. Connect your phone into the PHONE port of your Linksys ATA .
  2. Dial **** then 110#, the SPA-3102 will announce the current IP address
  3. Once you have the IP address of your SPA-3102 you can access the web interface by opening a web browser and typing the following in the Address: http:/ /< IP Address of SPA-3102> For example: http://192.168.1.10
Step 2: Access the USER1
  1. Go to Voice > Admin Login > Advanced
  2. If a username and password login appears enter username" admin, and your engin SIP password.
  3. If you decide to lock down the user side of the SPA-3102, the username is"user"




Step 3: Changing USER 1 configuration
  1. Go to the USER1 tab
  2. Insert a number for distinctive ring. For example, 039012*,039013* for Ring 2
  3. Submit all changes.

Others in this Category
document SPA-3102 Vertical Service Activation Codes
document How do I setup a dial plan to block mobile calls from my SPA-3102?
document How do I setup the PSTN to VoIP gateway feature on the SPA-3102?
document I have a Linksys SPA- 3102, how do I block my Caller ID permanently?
document I have a Linksys SPA- 3102, how do I add terminate other calls thru my PSTN service provider?
document I have a Linksys SPA- 3102, how do I setup a feature to block and unblock my engin Caller ID?
document How do I setup a speed dial for my Linksys SPA-3102?



RSS