Search VoIP Help:     Adv search
Browse by Manufacturer:
KB Number

How do I setup multiple ATA's to use the engin service behind one NAT firewall?

Views: 329
Votes: 1
Posted: 12 Sep, 2007
by: Engin *.
Updated: 03 Jan, 2008
by: Engin *.
To setup multiple ATA 's to the engin network, you will need to change the SIP and RTP ports incrementally under the SIP and LINE 1 tabs for your Sipura ATA .

For example, if you have 2 x Sipura SPA-2000's, you will need to setup 4 port forwarding rules and also change the SIP and RTP ports respectively for each ATA .  For simplicities sake, we have called the first ATA " SPA Y" and the second ATA " SPA Z" in the following example.


For the first ATA
  1. Set up a port-forwarding rule for UDP 5060-5061 to be forwarded to your "SPA Y" IP address
  2. Set up a port-forwarding rule for UDP 16384 -16386 to be forwarded to your "SPA Y" IP address
For the second ATA
  1. Set up a port-forwarding rule for UDP 5062-5063 to be forwarded to your "SPA Z" IP address
  2. Set up a port-forwarding rule for UDP 16387 -16389 to be forwarded to your "SPA Z" IP address