Search VoIP Help:
Adv search
|
Browse by Manufacturer:
|
|
|
How do I configure the Grandstream HandyTone-386 ATA to the engin network? |
|
|
|
|
|
Views: 304
Votes: 0
|
|
Posted: 17 Dec, 2007
by: Engin *.
Updated: 17 Dec, 2007
by: Engin *.
|
|
Overview
Step 1: Discovering the Grandstream HandyTone-386 ATA
IP address
- Dial *** followed by 02 on your telephone keypad or check your DHCP table by logging into the router which the 386 is connected to.
- You will hear the IP address
with the zeros. For Example: You hear 192.168.001.101 but you write 192.168.1.101
Step 2: Login to the Grandstream HandyTone-386 ATA
- Now you have the IP address
so go to your web browser.
- Enter the username: 123 and the password: admin
Step 3: Configuring the Grandstream HandyTone-386 ATA
- Go to FXS
Port 1
- SIP Server: byo.engin.com.au
- Outbound Proxy: syd.byo.engin.com.au
- SIP User ID: 0280040000
- Authenticate ID: 0280040000
- Authenticate Password: SIP password
- Name: Engin Customer
- Use DNS SRV: Yes
- User ID is phone number: Yes
- SIP Registration: Yes
- Unregister On Reboot: No
- Register Expiration: 1800
- local SIP port: 5060
- local RTP
port: Use random port: Yes
- DTMF Payload Type: Send DTMF: via RTP
(RFC2833)
- Preferred Vocoder: (in listed order) G729A/B, G711a (PCMA)
- Silence Suppression: No
- Fax Mode: T.38 (Auto Detect)
- All other options leave as default
Step 4: Advanced Settings
- FXS
Impedance: Australia/New Zealand #1 (220 Ohm + 820 Ohm||120nF)
- Caller ID Scheme: Bellcore
- Onhook Voltage: 36V
- Polarity Reversal: No
- NTP
Server: au.pool.net.org

|