Overview
Step 1: Login to your Netcomm N24W
- Login to your Netcomm N24W with the current IP address
assigned by your NAT enabled router. I.e 192.168.0.4
- Enter the username: user and password: 0000
Step 2: Setup SIP settings
- Go to SIP > SIP settings
- For SIP proxy Use: byo.engin.com.au
- For SIP proxy port use: 5060
- For Registar Address Use: byo.engin.com.au
- For Expiry Time Use: 1800
- For Session Timer Use: 0
- For Display Name Use: (Your engin number) i.e: 0280040000
- For SIP format, use NORMAL
- For Outbound proxy Use: syd.byo.engin.com.au
- For Register Name Use: (Your engin number) i.e: 0280040000
- For Register Password Use: Your 8 character SIP password.
- Click Save
- Next Go to SIP > SIP settings
- Enter your SIP URI which is just your engin number again.
- Click Save
Step 4: SDP settings (codecs)
- Next Go to SIP > SDP Settings
- Enter packet
size: Small
- Enter UDP port: 5060
- Enter RTP
port: 16384

|